RCRecallCheck

Official recall atom

Lighting chain — CL001-8, HLEDL 500

Official fact2026-05-22EU Safety GateMaterialised slice

Results are official records from named sources. Coverage is incomplete. This site is not medical advice and does not publish drug labels, openFDA, Prop 65 or NIH DSLD records.

Official action

Source. EU Safety Gate

Official identifier. SR/01424/26

Date. 2026-05-22

Jurisdiction. Croatia

Hazard (official). The product has inadequate insulation and there is insufficient protection against water. Additionally, the cross-sectional area of the electrical conductors is insufficient. Due to insufficient creepage distances, there is a risk of electrical breakdown between conductive parts. The user could touch accessible live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60598-1 and EN 60598-2-20.

Action / remedy (official). Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 08/05/2026

Model. CL001-8, HLEDL 500

Official record

Licence: European Commission Safety Gate reuse notice

Attribution: Alerts from the Rapid Alert System for dangerous non-food products, published free of charge on the Safety Gate website © European Union; use the current year range in the source disclaimer

Related paths