Jurisdiction. Germany

Hazard (official). The adaptor has an earthed socket, but it uses a two-pin plug and has no protective conductor. This means a class I appliance can be connected without proper earthing. If a fault occurs, the connected appliance could become live, and the user could receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 62368-1

Action / remedy (official). Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown