RCRecallCheck

Official recall atom

Product Safety Report: Telescopic Ladder sold via Amazon (2608-0058)

Official fact2026-08-17UK Office for Product Safety and StandardsAtlas binding present

Unmatched ≠ safe. A missing record is not a safety clearance. Coverage is incomplete and dated. This site is not medical advice and does not publish drug labels, openFDA, Prop 65 or NIH DSLD records.

Official action

Source. UK Office for Product Safety and Standards

Official identifier. opss-2608-0058

Date. 2026-08-17

Jurisdiction. UK

Hazard (official). The product presents a serious risk of injuries as the ladder could not hold the claimed weight without collapsing. If the ladder were to collapse while in use, the user could fall and receive serious injuries. The dimensions of the ladder were noncompliant, and the ladder allowed different distances between rungs while in use. There is also no protection in place to prevent squeezing when the ladder is being collapsed. The product also requires improvements to marking and labelling. Improvements are also required to the product’s required information and instructions. The product does not meet the requirements of the General Product Safety Regulations 2005.

Action / remedy (official). The import has been rejected at the border. The listing has been removed by the online marketplace (Amazon).

Official record

Licence: Open Government Licence v3.0